[fix](trx-frontend-http): measure auto squelch from the meter
Auto took the spectrum's noise floor and added 6 dB, but the threshold
is compared against the channel level the meter reports, and the two sit
a long way apart: the gap is set by the FFT size and window, the channel
bandwidth, the decimation, and peak-versus-mean statistics.  Measured on
white noise it runs +22.1 dB at 48k/8k/3k, +18.7 dB at 240k/24k/12k and
-1.2 dB at 1.92M/24k/12k — a 23 dB swing across ordinary configurations.
Only the last of those is anywhere near right, so on a narrow span Auto
set the gate some 20 dB below the noise and it never closed.

It now reads the same number the DSP compares: the 20th percentile of
the meter over the last ten seconds, plus 5 dB.  The percentile keeps a
burst of traffic inside the window from dragging the estimate up, and
5 dB clears the meter's own jitter, which measured 0.9-1.6 dB.  Nothing
in it converts between scales, so no part of the signal chain can put it
out again.  With no history yet — a fresh connection, a rig switch — it
listens for a moment rather than refusing.

The fixture gained a streaming /meter, without which there is nothing to
measure, and the spectrum test pins auto to the meter it serves.