c1899229a040a294839460b4d5e271d30e7f9821
7
Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
c1899229a0 |
[fix](trx-frontend-http): stop the decode history replay giving up at 20s
Reloading a second time sometimes showed history the first load did not, and the safety valve is why: it called one function that both released the buffered live decodes and tore the history worker down, so any load where the replay had not finished inside twenty seconds — a large backlog, a cold cache, a slow link — dropped whatever had not arrived, without a word. A reload got another go at it, and the second one is faster because everything is cached by then. Those are two separate things now. At the timeout the live decodes are released so the panels are not held back, the replay carries on, and the progress says so. The fallback's error path retries once and then says "Decode history unavailable" rather than leaving the operator to guess whether there was anything to see. The progress is no longer a scrim. It was fixed to the whole viewport with a wash over the page — the waterfall, the decode panels, all of it — for the length of the replay, which is exactly when there is something worth watching. It is a corner card with a bar: indeterminate while the payload is on the wire, then filling as N of M messages replay. None of this was reachable from a test. /decode/history answers in CBOR and the worker reads the body as CBOR unconditionally, but the fixture served JSON, so every browser run had been exercising the client's retry path and never its history path. It encodes CBOR now, including the 64-bit form the millisecond timestamps need, and decode-flow serves 1200 records and holds the client to restoring all of them on the first load, showing progress while it does, and never covering the page with it. Signed-off-by: Stan Grams <sjg@haxx.space> |
||
|
|
84a99a3636 |
[fix](trx-frontend-http): load the decoders that own the digital modes panels
AIS, VDES and both APRS decoders were listed under the map plugin group alone, so opening Digital modes and clicking AIS or APRS gave an empty panel reading "Connected, listening for packets" while the decodes piled up unprocessed in the plugin runtime. They appeared only if something had opened the Map tab first, which flushed the queue. There is also a map-data group naming exactly those four that nothing loads: the loader is called with tab names and no tab is called map-data. They load with the tab whose panels they fill now. map-core stays lazy, since their calls into it are optional and the Map tab can go on paying for Leaflet by itself. tests/decode-flow.mjs follows a decode from the wire to the map: an AIS vessel and an APRS beacon arrive on /decode, and it asserts both panels fill with the map module confirmed absent, the mini view names the vessel and offers a pin, following that pin lands on /map centred on the vessel, and both decoders leave a marker. Nothing exercised any of this before — the fixture served an empty decode stream, which is how the map links came to be broken for every decoder at once. The fixture stamps decodes as it sends them, since the client prunes anything outside the retention window, and repeats them, since the views collapse by vessel and need more than one frame to behave. Signed-off-by: Stan Grams <sjg@haxx.space> |
||
|
|
2c1df75d19 |
[fix](trx-frontend-http): measure auto squelch from the meter
Auto took the spectrum's noise floor and added 6 dB, but the threshold is compared against the channel level the meter reports, and the two sit a long way apart: the gap is set by the FFT size and window, the channel bandwidth, the decimation, and peak-versus-mean statistics. Measured on white noise it runs +22.1 dB at 48k/8k/3k, +18.7 dB at 240k/24k/12k and -1.2 dB at 1.92M/24k/12k — a 23 dB swing across ordinary configurations. Only the last of those is anywhere near right, so on a narrow span Auto set the gate some 20 dB below the noise and it never closed. It now reads the same number the DSP compares: the 20th percentile of the meter over the last ten seconds, plus 5 dB. The percentile keeps a burst of traffic inside the window from dragging the estimate up, and 5 dB clears the meter's own jitter, which measured 0.9-1.6 dB. Nothing in it converts between scales, so no part of the signal chain can put it out again. With no history yet — a fresh connection, a rig switch — it listens for a moment rather than refusing. The fixture gained a streaming /meter, without which there is nothing to measure, and the spectrum test pins auto to the meter it serves. Signed-off-by: Stan Grams <sjg@haxx.space> |
||
|
|
aefd36c4b1 |
[feat](trx-frontend-http): set the squelch on the spectrum, in dB
The threshold is in dB, and since the squelch fix that is the scale the spectrum axis and the S-meter are labelled in — so the control belongs on the plot, at the level it gates. A dashed line spans the spectrum at its threshold with a grip that reads it out, dragged like the bandwidth edges, green while the signal is above it and amber while it gates. Arrow keys move it a dB at a time for anyone not using a mouse. The audio row keeps a compact version: the dB, an indicator lit from the same meter the DSP compares against, Auto, and an enable toggle that no longer doubles as the level. The slider ran 0-100% over that dB range, which gave the operator a number with nothing on screen to relate it to, and zero meant "disabled", so turning the squelch off to listen threw the threshold away. Auto now says which level it picked. Two things the browser could only show once it was on the plot: the grip landed underneath the split control at the right edge, which swallowed its pointer, and dragging to the foot of the axis hid the line — and the grip with it — instead of pinning it where it could be dragged back. The fixture could not exercise any of this: /audio answered 404, which hides the audio row and the control inside it, and the status carried no filter block, which is what tells the client the rig has a squelch at all. Both now look like an SDR, and the spectrum test drives the line. Signed-off-by: Stan Grams <sjg@haxx.space> |
||
|
|
4fa191e9b6 |
[fix](trx-frontend-http): serve the band plan to every session
/bandplan.json needed the control role. Route access is decided by suffix for static assets — .js, .css, .png and so on — and ".json" is not among them, so the band plan matched nothing and fell through to the catch-all. It is compiled into the binary and identical for every user, so it is public now, like the rest of them. Two things followed from that. Read-only sessions never saw a band plan at all. And since the page asks for it during startup, the request can land before the session is established: that 401 was swallowed by an empty catch and never retried, which is why the allocations sometimes only appeared after a manual reload. So the client no longer hides the failure, retries once the auth gate clears — which is exactly when a startup 401 becomes fixable — and schedules a draw when the data lands, since the strip is painted from the spectrum draw and a rig sitting between frames would stay blank. The fixture can now refuse the first request the way the server did, and the spectrum layout test holds the client to recovering from it. Signed-off-by: Stan Grams <sjg@haxx.space> |
||
|
|
e70e82c8c0 |
[feat](trx-frontend-http): rebuild the general radio controls row
Mode was a full-width select: 483px of the row to display "FM". The modes are three or four characters and there are at most twelve, so they become a segmented group like the Unit and Step Scale pickers beside them — a third of the width, and one click instead of two. The <select> stays as the mode's value. A dozen call sites and several plugins read #mode.value, so replacing it outright would have reached much further than a layout change should; it is hidden from sight and from assistive tech, the buttons write to it, and everything downstream runs unchanged. Every writer re-syncs the buttons, the plugins through a new trxCore.syncModePicker. The row itself was a grid with a track per column, but the WFM, SAM and transmit columns are hidden on most rigs, so it ended in some 500px of hole. It packs left now. Same fault one level down: the power buttons sat in three fixed tracks, so a rig with neither transmit nor lock kept two empty ones and left its label chip stranded at the far edge. Unit and Step Scale move out of the frequency row and in beside the wheel and the +/- they modify, which were some 600px away. Signed-off-by: Stan Grams <sjg@haxx.space> |
||
|
|
1f256cbb68 |
[refactor](trx-frontend-http): extract the browser test fixture
browser-smoke.mjs carried its static server inline, which made it the only browser test that could exist: a second one would have had to copy 180 lines of routes to change a single capability flag. The server moves to tests/web-fixture.mjs behind startWebFixture(), with the rig's spectrum support, bookmarks and band plan as options. Serving a rig with a spectrum matters because that is where the layout actually lives — the panel, the strips above it and the waterfall are all gated on filter_controls, and the existing fixture reports a CAT-only rig, so none of it has ever been rendered under test. No change to what the smoke test checks. Signed-off-by: Stan Grams <sjg@haxx.space> |