[fix](trx-rds): tune acquisition speed vs false-positive tradeoff
- Increase phase candidates 4 -> 16 for faster clock-phase lock - Lower MIN_PUBLISH_QUALITY 0.65 -> 0.55 for earlier decode on weaker signals Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com> Signed-off-by: Stan Grams <sjg@haxx.space>
This commit is contained in:
@@ -12,10 +12,10 @@ const RDS_SYMBOL_RATE: f32 = 1_187.5;
|
||||
const RDS_CHIP_RATE: f32 = RDS_SYMBOL_RATE * 2.0;
|
||||
const RDS_POLY: u16 = 0x1B9;
|
||||
const SEARCH_REG_MASK: u32 = (1 << 26) - 1;
|
||||
const PHASE_CANDIDATES: usize = 4;
|
||||
const PHASE_CANDIDATES: usize = 16;
|
||||
const BIPHASE_CLOCK_WINDOW: usize = 128;
|
||||
/// Minimum quality score to publish RDS state to the outer decoder.
|
||||
const MIN_PUBLISH_QUALITY: f32 = 0.65;
|
||||
const MIN_PUBLISH_QUALITY: f32 = 0.55;
|
||||
/// Tech 6: number of Block A observations before using accumulated PI.
|
||||
const PI_ACC_THRESHOLD: u8 = 3;
|
||||
/// Tech 5 — Costas loop proportional gain (per sample).
|
||||
|
||||
Reference in New Issue